NOXtec 2000

NOXtec 2000

Semi automatic/manual dispenser
and Nitric Oxide monitor.

NOXtec 2000 is a device that allows both semi-automatic dosing and monitoring of inhaled nitric oxide.

Nitric Oxide (NO) is a gaseous vasodilator used primarily to treat pulmonary arterial hypertension, delivered to the patient in a mixture with medicinal oxygen. NOXtec 2000 delivers a dose that remains stable throughout the therapy.

NOXtec 2000

Semi automatic/manual dispenser

NOXtec 2000 semi automatically calculates the dose flow necessary to reach the desired PPM concentration, thanks to the disposable respiratory flow sensor that is installed in the patient’s breathing circuit. Alternatively, the dose rate can be set manually.

By continuously sampling the flow of the NO-O2 mixture delivered to the patient, the NOXtec 2000 is able to monitor the concentration of nitric oxide that the patient is receiving and whether it is within predetermined threshold values.

NOXtec 2000
Semi automatic/manual dispenser

NOXtec 2000 is able also to monitor the trace amount of nitrogen dioxide (NO2) in the mix, a highly toxic gas that can compromise patient safety during the application of the therapy, so that a predetermined threshold value is not exceeded.

NOXtec 2000 is able to calibrate automatically the NO, NO2 and O2 sensors, even when the device is dosing, leading to a significative reduction in management costs (standard devices on the market needs manual calibration).

Dose System Monitor System
REAL TIME MODE AUTOMATIC MODE SEMIAUTO. MODE MANUAL MODE CYLINDER EXCHANGE AUTOMATIC VENTING AUTOMATIC CALIBRATION ROOM MEASUREMENT

NOXtec 2000 is ready to use!

At the start of the device is not required 
any calibration test before beginning of the therapy, saving time and allowing 
rapid initiation.

NOXtec 2000 integrates unique security features:
  • Emergency Manual Dosing

    Even when the device is off

  • Measurement 
System

    Of the concentration of NO, NO2 and O2 in the room, even when 
the device is dosing

  • Purge Outlet

    To gather and canalize the residual gas

Cart and other accessories
  • The cart can transport till 2 cylinders 
of mixture NO-N2 till 20 liters of volume.
  • Automatic cylinder exchange permits to increase 
the treatment autonomy and optimize the gas consumption.
  • Consumable kits supplied allow the connection 
of the device to all kind of ventilators.
  • Easy to move thanks to the swivel wheels.
Portable NOXtec medical gas delivery device with integrated monitor and gas cylinder mounted on a wheeled cart.